System restore
18
System restore
There are two push buttons on the lower parts of the central controller printed circuit board (inside the
metal box). One (RESET) is used to reboot the system. The other one (PGM) is used to perform a restore
to factory default settings.
To perform a system reset
1. Push the (RESET) button once. The system will reboot and enter a 30 second delay.
To perform a restore to factory default
1. Push the (RESET) button once. The system will reboot and enter a 30 second delay. Go to the
Secant touch screen during this 30 second delay.
2. At the end of the 30 second delay, a countdown appears on the screen to allow the entry into
diagnostic mode. Touch the screen during this countdown and the system enters into diagnostic
mode. (To check if you really entered into diagnostic mode, you are supposed to see all the 16
alarm zones with their current status and the system voltage on the screen.)
3. Once the system is in diagnostic mode, go back to the central controller and push 6 times on the
(PGM) button. The system now comes back to factory default and a message appears on screen.
!WARNING!: A system restore to factory default will completely erase all the
programming of the system.
Modification / Loss of installer code
The installer code by default is 00000. It is possible to modify it on the CODE section of the programming
screen after entering the current valid installer code. Once the installer code has been modified, should it
be lost, the only way to enter again on the installer advance programming menu will be to perform a
restore to factory default (see above).
!WARNING!: by doing a system restore, the installer code will automatically come
back to its original value (00000) AND all the system programming will be erased!
NOTE: The installer code is not valid to disarm the security function.